Technical Specification of Bulk Milk Cooler Capacity –2000 Liters

DESCRIPTION 2000 Liters A MILK TANK 

1 Rated Capacity Liters 2000
2 Gross Capacity Liters 2200
3 Make Numaan/  Ashwin
4 Model OHT 2000
5 Material Of Construction (AISI) AISI 304 Stainless Steel
6 Shape & Orientation Open Horizontal Tank
7 Overall Dimensions (mm) 1800(L) x 1600(W) x 1800(H)
8 Weight 345 Kgs
9 Thickness Of Inner & Outer Shells 1.5 mm Inner and 1.5 mm Outer
10 Number of Agitator 1
11 RPM of Agitator 23 Rpm 12 CIP Facility Manual, Cleaning Brushes Would Be Provided 13 Type Of Insulation (Injected CFC Free PUF) Injected, CFC Free PUF, Density 40 kg/m³ As Per ISO 5708 2A(II) 14 Thickness Of Insulation 50 mm 15 Efficiency 0.019w.m/K 16 Facility To Measure Volume SS Calibrated Dip Stick (1 no.) Along With Laminated Calibration Chart 17 Calibration Accuracy 0.50% 18 Surface Finish (Grits) 150 B
REFRIGERATION UNIT
1 Type of Expansion Direct Cooling DX Type
2 Make of Compressor Emerson
3 Model/Type of Compressor CR 36 x 2 Emerson, Reciprocating
4 Size (Nominal HP) Of Compressor 3.0 HP x 2
5 Number Of Compressors 2
6 Cooling Cap of Compressor (Kcal/Hr) Min 7535 Kcal/hr For Each Compressor
7 Make Of Condenser Emerson
8 Model Of Condenser CR 36 x 2 Emerson
9 Size Of Condenser 26″ x 22″ x 4 Rows
5 Number Of Compressors 2
6 Cooling Cap Of Compressor (Kcal/Hr) Min 7535 Kcal/hr For Each Compressor
7 Make Of Condenser Emerson
8 Model Of Condenser CR 36 x 2 Emerson 9 Size Of Condenser 26″ x 22″ x 4 Rows
9 Size Of Condenser 26″ x 22″ x 4 Rows
10 Number of Condenser 2
11 Capacity Of Condenser 7535 kcal/hr For Each Compressor
12 No. Of Fans 2
13 Receiver Size/Capacity Ø150 mm 400 mm Cap-6 L x 2
14 TX Valve Make,Capacity Size TEX2-Danfoss Make Size- 3/8″
15 Overall Dimensions (mm) 1000 x 800 x 800 – 2
16 Total Weight (kg) 107 x 2
17 Type Of Refrigerant R22 Or As Per Requirement
18 Type Of Welding On Evaporator Laser Welding
DESIGN PARAMETERS
1 Ambient Temperature Consideration For Design 46 ° C
2 Maximum Cooling Time Considered For (a) All Milking 3.0 hrs (b) Second Milking 1.5 hrs
3 Temperature Range Considered (a) All Milking 35°C to 4°C (b) Second Milking 10°C to 4°C D
ELECTRICALS Single Phase 1 Connected Load In Watts & Amperes For:
(a) Compressor(s) 4500 watt / 11 – 13 A
(b) Condenser Fan (s) 750 Watt / 3.5 A
(c) BMC Agitator (s) 90 Watt / 0.5 A
(d) BMC Milk Pump 750 Watt / 3.5 A ( e) Water Heater (if any) 2000 Watt / 9 A 2 Power Consumption (Kw/Hr) 6 Kw/hr 3 Max. Surge Current Drawn by Compressor 20 A