KSh1,235,535.00

Description

A.Technical Specification Of Bulk Milk Cooler Capacity –3000 Liters Description 

1 Rated Capacity 3000 L
2 Gross Capacity 3300 L
3 Make Krishna
4 Model CCT 3000
5 Material of Construction AISI 304 Stainless Steel
6 Shape & Orientation Closed Horizontal Cylindrical Tank
7 Overall Dimensions 2850(L) x 1470(W) x 1975(H)
8 Weight 550 Kg
9 Thickness of Inner & Outer Shells 2.0 Mm Inner and 1.5 Mm Outer
10 Number Of Agitators 1
11 RPM of Agitator 23 RPM
12 CIP Facility CIP with Self Rotating Spray Ball
13 Type of Insulation (Injected CFC Free PUF) Injected CFC Free PUF, Density 40 Kg/m³ As per ISO 5708 2AII
14 Thickness Of Insulation 50 Mm
15 Insulation Efficiency 0.019 w.m/°K
16 Facility To Measure Volume SS 304 Dip Stick Along With Laminated Calibration Chart
17 Calibration Accuracy 0.50%
18 Surface Finish 150 B Refrigeration Unit
 1 Type of Expansion Direct Cooling DX Type
 2 Make of Compressor Emerson /Equivalent
 3 Model/Type of Compressor CR53, Hermetically Sealed Reciprocating
 4 Size (Nominal HP) of Compressor 4.5 HP x 2
 5 Number Of Compressors 2
 6 Cooling Capacity Of Compressor Min 11250 Kcal/hr For Each Compressor
 7 Make of Condenser Emerson or Equivalent
 8 Model of Condenser CR 53/Equivalent 9 Size of Condenser 41″ x 24″ x 4 Rows Or Suitable To Match the Compressor 10 Number of Condensers 2
11 Capacity Of Condenser 12000 Kcal/hr F
Or Each Condenser
12 Number Of Fans 4
13 Receiver Size/Capacity Ø180 x 500 mm / 9 Liter
14 Expansion Valve: Make/Model/Size TEX2 Size 3/8″ Danfoss Make
15 Overall Dimensions 1200 (L) x 800 (W) x 850 (H) mm
16 Total Weight 140 Kg 17 Type of Refrigerant R22
18 Type Of Welding On Evaporator Laser Welding
Design Parameters 
1 Ambient Temperature Consideration for Design 46 ° C
2 Maximum Cooling Time Considered For
(a) First Milking 3.0 Hrs
(b) Second Milking 1.5 Hrs
3 Temperature Range Considered
 (a) First Milking 35°C to 4°C
 (b) Second Milking 10°C to 4°C D
Electrical s Three Phase Operating Power 3 ɸ 415 V 50 Hz AC with Neutral And Earthing 1 Connected Load In Watt & Ampere For:
(a) Compressor(s) 7000 Watt / 13 – 15 Amp
(b) Condenser Fan (s) 1500 Watt / 7 Amp
(c) BMC Agitator (s) 90 Watt / 0.5 Amp 2 Power Consumption (Kw/Hr) 9 Kw/Hr
2 Power Consumption (Kw/Hr) 9 Kw/hr 3 Max. Surge Current Drawn By Each Compressor 11 Amp
Fob Usd$12300

Reviews

There are no reviews yet.

Be the first to review “Bulk Milk Cooler Capacity –3000 Liters (Model Numaan / Ashwin )”

Your email address will not be published. Required fields are marked *