KSh1,687,560.00

Description

A.Technical Specification of Bulk Milk Cooler Capacity –5000 Liters

1 Description 5000 Ltrs A Milk Tank 1 Rated Capacity 5000 L

2 Gross Capacity 5500 L
3 Make Numaan / Ashwin
4 Model CCT 5000
5 Material of Construction AISI 304 Stainless Steel
6 Shape & Orientation Closed Horizontal Cylindrical Tank
7 Overall Dimensions 3650 (L) x 1670 (W) x 2275 (H)
8 Weight 750 Kg
9 Thickness of Inner & Outer Shells 2.0 mm Inner and 1.5 mm Outer
10 Number Of Agitators 1
11 RPM of Agitator 23 RPM
12 CIP Facility CIP With Self Rotating Spray Ball
13 Type Of Insulation (Injected CFC Free PUF) Injected CFC Free PUF, Density 40 Kg/m³ as per ISO 5708 2AII
14 Thickness Of Insulation 50 mm
15 Insulation Efficiency 0.019 w.m/°K

16 Facility to Measure Volume SS 304 Dip Stick Along With Laminated Calibration Chart 17 Calibration Accuracy 0.50% 18 Surface Finish 150 B Refrigeration Unit
1 Type of Expansion Direct Cooling DX Type
2 Make Of Compressor Emerson / Equivalent
3 Model/Type of Compressor ZB48, Hermetically Sealed Scroll
4 Size (Nominal HP) of Compressor 7.5 HP x 2
5 Number of Compressors 2
6 Cooling Capacity of Compressor Min 18000 Kcal / hr per Compressor
7 Make Of Condenser Emerson Or Equivalent
8 Model Of Condenser ZB 48 / Equivalent
9 Size Of Condenser 41″ x 24″ x 4 Rows Or Suitable To Match The Compressor
10 Number of Condensers 2
11 Capacity of Condenser 18500 Kcal/hr
12 Number of Fans 4
13 Receiver Size/Capacity Ø180 x 500 mm / 9 Liter
14 Expansion Valve: Make/Model/Size TEX2-Danfoss Make Size- 3/8″
15 Overall Dimensions 1035 (L) x 430 (W) x 925 (H) mm
16 Total Weight 91 Kg
17 Type of Refrigerant R 22
18 Type of Welding On Evaporator Laser Welding C Design Parameters
1 Ambient Temperature Consideration For Design 46 ° C
2 Maximum Cooling Time Considered For
(a) First Milking 3.0 Hrs
(b) Second Milking 1.5 Hrs 3 Temperature Range Considered
(a) First Milking 35°C to 4°C
(b) Second Milking 10°C to 4°C
 E Electrical s Three Phase Operating Power 3 ɸ 415 V 50 Hz AC With Neutral And Earthing 1 Connected Load In Watt & Ampere For:
 (a) Compressor(s) 11250 watt / 10.5 – 11.5 Amp
 (b) Condenser Fan (s) 1500 Watt / 7 Amp
 (c) BMC Agitator (s) 90 Watt / 0.5 Amp
 (d) BMC Milk Pump 750 Watt / 3.5 Amp
 (e) Water Heater (If Any) 2000 Watt / 9 Amp 2 Power Consumption (Kw/Hr) 14.5 Kw/hr 3 Max. Surge Current Drawn by Each Compressor 16 Amp